300mA 500mA X-Ray Units

The 300 mA and 500 mA X ray units we offer are suitable for radiography, fluoroscopy and spot filming. Our range of 300mA 500mA X-Ray units includes Multi Diagnoste 300, DMS-HF200 High Frequency X-Ray unit and High Frequency Generator And Console. These X ray units are used to produce electromagnetic radiations, collect them and finally developing the X ray images. The X ray units have dense walls usually made of lead so as to absorb the X rays that is being produced. Given below are the specifications of the X ray machines we provide:

REQUEST CALLBACK
Ask Latest Price

Product Price: Get Latest Price

Quality being our priority, we use fine quality raw materials for manufacturing Multi Diagnoste 300. Offered to clients at a very reasonable price, the offered product is one of the first preferences in the market. Its impeccable performance in radiography, fluoroscopic and spot filming is highly acclaimed. The offered units are designed as per the latest technology.

Features:

  • Full wave rectifications.
  • Digital display of MA, KV, & MAs
  • Automatic computation of MAs

 

Yes! I am Interested
REQUEST CALLBACK
Ask Latest Price

Product Price: Get Latest Price

Finding application in a number of hospitals and nursing homes, the offered DMS-HF200 High Frequency X-Ray Unit is used for the purpose of radiography. Manufactured using high quality raw materials and advanced technology, the offered unit provides impeccable performance and an extraordinarily long functional life. These units are competitively priced.

Features:

  • Long service life
  • Intricately designed
  • Durable

Specifications:


  • Voltage: 380V, 50Hz
  • HV frequency at conversion: 50KHz
  • Max. Output of power: 20kW
  • Max. Tube voltage: 125kV
  • Max. Tube current: 200mA(current range: 80-200mA)
  • Max. MAs: 320mA
  • X-ray tube: Small focus 1.0mm; Big focus 2.0mm
  • The height of table top to ground: 690mm
  • Horizontal movement distance of table top: 220mm
  • Vertical movement distance of table top: 900mm
  • Vertical movement distance of filter: 540mm
  • Suitable for the loading of various X-ray Cassettes
  • Focus-film distance of X-ray tube assembly: 60-1210mm
  • The rotation range of X-ray tube assembly around the center of pillar: 3 steps
  • The rotation range of X-ray tube assembly around the center of horizontal arm: 90
  • The vertical movement along pillar of X-ray tube assembly: 980mm
  • The horizontal movement along ground rail of X-ray tube assembly: 1320mm
  • Beam limiter is equipped with point light and 30s delay mechanism;
  • Ray-filter grid: Grid ratio is 10: 1, grid density > 40 lines/cm
Yes! I am Interested
X
 

Download Brochure
Explore more products
Examination Lamp
Get Best Quote
Lead Apron
Get Best Quote
Fiber Optic Otoscope
Get Best Quote
Taylor Reflex Hammer
Get Best Quote
Dhanwantari Medical Systems

O. P. Singh(Director)
5/8, Rajni Niwas, Gala No. 4, Ramnagar Near Guru Gobindsingh Industrial Estate, Jogeshwari East
Mumbai - 400060
Maharashtra, India
Send Email
© Dhanwantari Medical Systems. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited